Eusol-C is a completely synthetic media for corneal storage at 4°C for up to 14 days.
What is EUSOL-C?
Eusol-C is a completely synthetic media for corneal storage at 4°C for up to 14 days.
The solution contains a single antibiotic at an effective dose for a higher stability of the media. Before use, the product can be stored at room temperature and it can stand peak temperatures during transport. The phenol red indicator allows a rapid visualization of the pH variations.
The optically clear vial bottom allows to evaluate the cornea by specular microscopes (e.g. Konan, Hailabs) with no need to transfer it to another container, thus reducing the risk of contamination.
Intended use
CORNEAL STORAGE AT 4°C
Characteristics
ENDOTOXIN-TESTED < 0,5 EU/ml
SHELF-LIFE: 24 MONTHS
DURATION OF USE: UP TO 14 DAYS
CLEARED FOR SALE IN THE UNITED STATES
Technical Documents
Technical Sheet - CSM-001 514.17 KB 1387 downloads
Eusol-C, media for corneal storage at 4°C - 12 x 20 ml ...Publications and Presentations
Clinical outcomes of long-term corneas preserved frozen in Eusol-C used in emergency tectonic grafts
Year: 2022 Authors: Burgos-Blasco B.; Vidal-Villegas B.; Collado-Vincueria I.; Soria-García A. M.; Cuiña-Sardiña R.; Mendez-Fernandez R.; Diaz-Valle D.; Ariño-Gutierez M. Cell Tissue Bank doi.org/10.1007/s10561-022-10037-1 Online version This is a: Publication To report the clinical results [...]
Porcine cornea ex vivo model as an alternative to human donor tissues for investigating new preservation conditions
Year: 2023, EEBA Authors: Rodella U.; Bosio L.; Ferrari S.; Gatto C.; Giurgola L.; Rossi O.; Ciciliot S.; Ragazzi E.; Ponzin D.; D’Amato Tóthová J. PURPOSE Considering the growing shortage of corneal [...]
Descemet’s membrane endothelial keratoplasty (DMEK) graft preparation in porcine cornea
Year: 2023, EEBA Authors: Giurgola L.; Gatto C.; Rodella U.; D’Amato Tóthová J. PURPOSE Descemet’s membrane endothelial keratoplasty (DMEK) is a frequently used treatment option for patients with corneal endothelial dysfunction. The [...]
A porcine cornea and lamellar tissue model to investigate effects of storage conditions on corneal preservation
Year: 2022, European Eye Bank Association (EEBA) Authors: Rodella U.; Bosio L.; Giurgola L.; Gatto C.; Rossi O.; Ferrari S.; D'Amato Tothova J. BACKGROUND Globally, more than 12 million people are awaiting corneal [...]
Direct Evidence of Symmetry between Bilateral Human Corneas in Biomechanical Properties: A Comparison Study with Fresh Corneal Tissue
Year: 2021 Authors: Chao Xue; Yaoqi Xiang; Yi Song; Min Shen; Di Wu; Yan Wang Journal of Ophthalmology doi.org/10.1155/2021/8891412 Online version This is a: Publication Purpose. To investigate [...]
Metabolomic Signature Discriminates Normal Human Cornea from Keratoconus—A Pilot GC/MS Study
Year: 2020 Authors: Wojakowska A.; Pietrowska M.; Widlak P.; Dobrowolski D.; Wylęgała E.; Tarnawska D. Molecules 2020, 25(12), 2933 https://doi.org/10.3390/molecules25122933 Online version This is a: Publication The molecular etiology of [...]
Endothelial Safety and Efficacy of Ex Vivo Collagen Cross-linking of Human Corneal Transplants
Year: 2020 Authors: Lammer J.; Laggner M.; Pircher N.; Fischinger I.; Hofmann C.; Schmidinger G. Am J Ophthalmol doi: 10.1016/j.ajo.2020.02.024 Online version This is a: Publication Purpose: To assess endothelial safety and efficacy [...]
A new storage solution for the hypothermic preservation of corneal grafts: an experimental study
Year: 2020 Authors: Koulouri I.; Hellwinkel O.; Altenähr S.; Spitzer M.; Fritz S.; Feuerstacke J.; Filev F. Cell Tissue Bank doi: 10.1007/s10561-020-09838-z Online version This is a: Publication [...]
A new approach to extend the storage of donor corneas after 28 days of corneal culture in an Italian eye bank
Year: 2019 Authors: Mistò R.; D’Amato Tóthová J.; Khan S.; Limongelli A.; Pateri F. Cell Tissue Bank: 2020 Mar;21(1):47-55 doi: 10.1007/s10561-019-09795-2 Online version This is a: Publication This study aimed [...]
Monitoring the microbial contamination of donor cornea during all preservation phases: a prospective study in the Eye Bank of Rome
Year: 2018 Authors: Vignola R.; Giurgola L.; Colabelli Gisoldi R. A.M.; Gaudio M.; D'Amato Tóthová J.; Pocobelli A. Category: Microbiology Transplant Infectious Disease doi:10.1111/tid.13041 Online version This is a: Publication [...]
Evaluation of donor corneas preserved in a new cold storage medium with antimycotic tablet
Year: 2017, EEBA Authors: Pateri F.; Limongelli A.; Tomasiello D.; Giurgola L.; Gatto C.; D’Amato Tóthová J.; Mistò R. Introduction: A new cold storage medium (ECS) with an effective antimycotic concentration, fast [...]
Endothelial Cell Viability of Donor Corneas Preserved in Eusol-C Corneal Storage Medium
Year: 2015 Authors: Yüksel B.; Uzunel UD.; Küsbeci T. Exp Clin Transplant. 2015 Oct 14. doi: 10.6002/ect.2014.0295 Online version This is a: Publication Objectives: To evaluate the efficacy [...]
Metabolic changes in donor corneas during cold storage – challenging stereotypes
Year: 2015 Authors: Kryczka T.; Szaflik J.P.; Szaflik J.; Midelfart A. Integr Mol Med 2(4): 238-42, 2015 Online version This is a: Publication Abstract: It has been recently shown [...]
Preservação de córnea humana nos meios Eusol-C e Optisol-GS
Year: 2011, Faculdade de Medicina, Universidade Federal de Minas Gerais Belo Horizonte Author: Rodrigues Pereira L. Abstract: More than a decade has passed since the introduction of intermediate-term corneal storage media in Brazil. Two media [...]
Suitability for Transplantation of Corneas From Donors 76 to 80 Years Old
Year: 2009, EBAA Authors: Gangadhar D.; Abdullayev E.; Kalankhodjaev B.; Abdullayev A. Abstract: Older donor cornea (76-80 yrs old) were stored in Eusol-C and transplanted. None of the recipients developed postoperative endophthalmitis or other inflammatory [...]
New corneal preservation media. Eusol-C vs. Optisol-GS
Year: 2006, EBAA Authors: Chaibpracob J.; Phillips R.; Hardenbergh F. Abstract: Eusol-C is a widely used European media for cold corneal storage. In the present study we compared Eusol-C to Optisol-GS. Following transplantation, corneal [...]
Eusol-C effectiveness as a corneal storage media EEBA 2006
Year: 2006, EEBA Authors: Scott Bryan G.; Abdullayev E.; Wellemeyer M.; Gangadhar D. JR.; Sandlin C. Abstract: Eusol-C is an effective alternative corneal storage media to the more widely used Optisol-GS. Eusol-C maintained donor cornea [...]
Results of comparative investigations of corneas preserved in EUSOL-C medium and Borzenok-Moroz medium
Year: 2006, EEBA Authors: Borzenok, S.A.; Moroz, Z.I.; Komakh Y.A.; Kalinnikov Y.Y.; Kovshun E.V.; Volkova O.S.; Kozyr S.S. Abstract: A comparative analysis between Eusol-C and Borzenok-Moroz medium revealed a positive comparison of clinical and [...]
Eusol-C effectiveness as a corneal storage media
Year: 2005, EBAA Authors: Scott Bryan G.; Abdullayev E.; Wellemeyer M.; Gangadhar D. JR.; Sandlin C. Abstract: Eusol-C proved to be an effective alternative corneal storage media, maintaining donor corneal viability comparable with the more [...]
Preservación corneal con Eusol-C
Year: 2004, Congreso SETS Authors: Pallarés P.; Nualart R.; Torras J.; Pascual L.; Salvador A.; Moya F. Abstract: Corneal storage in Eusol-C at 4°C resulted in satisfactory clinical results. All transplanted corneas were clear, 3 [...]
Related products
Request info about EUSOL-C
Request info about EUSOL-C
Additional information
Packaging | Vial |
---|---|
Items | 12 |
Volume | 20 ml |